Leakage test recorder of gas domestic plants according to DVGW TRGI 86/96.Rechargeable battery power supply.PATENTED.
TECHNICAL SPECIFICATION |
|
Power supply | Rechargeable battery |
Autonomy of operations | 25 testing cycles approx. |
Pressure sensor | 250 hPa |
Precision | 10 Pa |
Max pressure sensor | 500 hPa |
Alarms | Low battery, low / high pressure and memory full |
Data logger | 150 cycles approx. |
PC / Printer connection | Serial RS 232 |
Display | LCD 2 x 16 carachters |
Operating temperature | -5 ÷ + 45 °C |
Storage temperature | -20 ÷ + 60 °C |
Protection degree | IP 65 (closed) |
Dimensions / Weight | 340 x 300 x 160 mm / 7 Kg ca. |
Reference norms | UNI 11137/1, DVGW-TRGI 86/96, UNI 7129/01, UNI 7131 |
ACCESSORIES |
|
Standard equipment | Battery charger, connection pipe and fittings and manual pump |
On request | See .pdf attached datasheet |
-
Test in according to DVGW TRGI 86/96 and UNI 11137/1
-
Suitable for test gas domestic plants up to 200 hPA
-
Easy to use
-
150 cycles internal memory
-
Built-in printer
-
Data transmission to PC
-
Splashproof housing IP 65
-
Complete with connection kit and battery charger
-
PATENTED